Close Menu
    Facebook X (Twitter) Instagram
    Trending
    • ⚡ Working of Solar Inverter: From Sunlight to Grid Power
    • ⚡ Working of Solar Inverter: From Sunlight to Grid Power
    • ☀️ Solar Photovoltaic (PV) Power Plants: Complete Guide
    • Power Sector Reform in Odisha (1990–2025)
    • Protection Schemes for 220/132/33kV Substations: Components, Design & Best Practices
    • Summer Power Outages: Common Causes & How to Prevent Them
    • Battery Energy Storage Maintenance in Summer Conditions
    • ⚡ Cable Types in Distribution: XLPE vs PILC vs Aerial Bundled Cables
    Electric Know How
    • Home
    • Generation
      • Hydropower Station
      • Thermal Power Station
      • DISTRIBUTED ENERGY SOURCES
      • Diesel Generator
      • Industrial Tools
      • DC System-Generating Stations
    • Transmission
      • High Voltage DC Transmission
      • High Voltage AC Transmission
        • Transmission line – An Overview
        • TRANSMISSION TOWER CONFIGURATION
        • Transmission Towers-Key Features
    • Distribution
      • ⚡ Understanding Electrical Distribution Systems: Basics to Architecture
      • ⚡ Top 5 Faults in Distribution Lines and How to Fix Them
      • 🛠️ Distribution Transformer Maintenance: Checklist and Tips
    • Protection
      • Protection Schemes for Grid Substations
        • Types of Fault in Power System
        • Relay Setting Calculation for Substation
        • Circuit Breaker
          • Nameplate details of SF6 Circuit Breaker
          • Major parameters of a circuit breaker
          • What is the use of an anti-pumping relay?
          • What is an IR Value Test in a Circuit Breaker? An overview
          • Testing of Circuit Breaker
        • Key Components of Control & Relay Panel
          • Relay Setting Calculation for Substation
          • Trip Circuit Supervision Relay
          • Three Phase Control Wiring
        • Switching Surges and Its Remedies
      • OVERVIEW OF TRANSFORMER PROTECTION
        • Differential Protection of Transformer
      • OVERVIEW OF GENERATOR PROTECTION
      • Distance Protection
      • Electrical Safety
    • Switchgear
      • Electrical Sub-Station
        • BATTERY SYSTEM IN GRID SUBSTATION
        • Operation of Float Cum Boost Charger
        • Protection Circuitry of Battery Charger
        • Power Transformer
          • INSULATION RESISTANCE OF TRANSFORMER
          • WTI AND OTI in Power Transformer
          • Transformer Oil Dielectric strength
          • On Load Tap Changing of Transformer
          • TRANSFORMER MAINTENANCE
        • Sub-Station Operation
        • Multiplying Factor for Energy Meter
      • Current Transformer
        • Nameplate Detail of Current Transformer – A Detail Guide
        • Current Transformer Knee Point Test – A Detailed Overview
        • What is a Current Transformer Polarity Test- Detailed Guide
        • Ratio test of Current Transformer
      • Potential Transformer
      • Isolator in Substation
        • Nameplate Detail of Isolators/Dis-connectors- A Detail Guide
      • Electrical Busbar
      • Insulators
      • Clamps and Connectors
      • Fire Fighting System
      • Surge Protection Devices in Transmission Grid Sub-Stations: Types & Applications
        • LCM Test of a Lightning Arrestor – An Overview
      • Gas Insulated Substation
        • Local Control Cubicle
        • SF6 circuit breaker gas compartment
        • Maintenance of GIS (Gas-Insulated Switchgear)
    • Q&A
      • FAQS ON Current Transformer
      • POWER SYSTEM
      • FAQ ON BUSBAR
    Electric Know How
    Home»Protection»SF6 circuit breaker gas compartment
    Protection

    SF6 circuit breaker gas compartment

    madhusmitaBy madhusmita24 November 2022Updated:12 April 2025No Comments2 Mins Read
    Facebook Twitter Pinterest LinkedIn Tumblr Email
    Share
    Facebook Twitter LinkedIn Pinterest Email

    CONSTRUCTION

    This is basically an aluminum compartment in which the circuit breaker is inbuilt.SF6 gas is to be filled in these compartments after complete installation.
    The lower point is the entry point for gas insulated bus and the upper point is the outgoing point of the gas-insulated bus. The lowermost point is for the cable link to local control cabinets to control the relay panel, from where the circuit breaker operation has to be controlled.

    The CB is designed and tested according to international standards and fulfills the appropriate requirements

    SF6 CB COMPARTMENT

    OPERATION OF CB IN GIS

    It consists of three vertically arranged self-blast interrupters mounted in a common enclosure and operated by a common spring operating mechanism.

    The three-phase circuit breaker unit and support structure form the mechanical basis of the GIS bay.

    The CB is applied for any GIS layout e.g. Single busbar and double busbar arrangements.

    When the interrupter is in the closed position the current flows through the circuit breaker via the outer current-carrying circuit.

    When the OPEN command is triggered, the blast cylinder starts to leave the contact crown of fixed contact, and the SF6 gas between the blast cylinder and piston is compressed.

    When the arcing contacts are mechanically separated, an arc burns between the moving and fixed arcing contacts.

    An intensive blast of SF6 Gas is pressed through the nozzle to extinguish the arc at the next current zero.

    1. DISTANCE BETWEEN ARCING CONTACTS MUST INCREASE VERY FAST

    2. ARC SHOULD QUENCH AT CURRENT ZERO CROSSING WITH BLAST OF SF6.

    3.RRDS(RATE OF RISING OF DIELECTRIC STRENGTH) SHOULD BE FASTER THAN RRRV(RATE OF RISING OF RESTRIKING VOLTAGE)DURING ARC QUENCHING

    A spring-operated mechanism is one driven by the mechanical energy stored in springs. Typically, the “closing spring” is mechanically charged by a motor and is held in its compressed position by a closing latch.

    When a close signal releases this latch, this spring pushes against a mechanical linkage to force the breaker contacts closed and, at once, charges the trip spring. The closing spring is then immediately recharged by the motor. Another latch will hold the tripping spring in the compressed position until an open signal releases this latch

    Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
    Previous ArticleGas Insulated Substation
    Next Article Local Control Cubicle
    madhusmita
    • Website
    • Facebook
    • Instagram
    • LinkedIn

    Related Posts

    ⚡ Understanding Distribution Protection: Fuses, Relays & Reclosers

    16 May 2025

    What is the use of an anti-pumping relay?

    22 July 2024

    Key Components of Control & Relay Panel

    25 May 2024

    Comments are closed.

    Archives
    Categories
    • Distribution (14)
    • Generation (12)
    • Protection (25)
    • Q&A (9)
    • Switchgear (51)
      • Nameplate Details (2)
    • testing (11)
    • Transmission (22)
    • Uncategorized (2)
    Recent Posts
    • ⚡ Working of Solar Inverter: From Sunlight to Grid Power
    • ⚡ Working of Solar Inverter: From Sunlight to Grid Power
    • ☀️ Solar Photovoltaic (PV) Power Plants: Complete Guide
    • Power Sector Reform in Odisha (1990–2025)
    • Protection Schemes for 220/132/33kV Substations: Components, Design & Best Practices

    Quick Links

    • Home
    • About Us
    • Contact Us

    Post Categories

    • Generation
    • Transmission
    • Distribution
    • Protection
    • Switchgear
    • Q&A

    Vip Link

    • Privacy Policy
    • Disclaimer
    • Terms and Conditions

    Contact Us

    • ele.mamohanty@optcl.co.in
    Linkedin