Close Menu
    Facebook X (Twitter) Instagram
    Trending
    • ⚡ Cable Types in Distribution: XLPE vs PILC vs Aerial Bundled Cables
    • ⚡ Smart Grid in Distribution: Role, Challenges & Indian Scenario
    • ⚡ Power Factor Correction in Distribution Systems
    • ⚡ Understanding Distribution Protection: Fuses, Relays & Reclosers
    • ⚡ Voltage Drop in Distribution Lines: Causes, Calculation & Correction
    • 🛠️ Distribution Transformer Maintenance: Checklist and Tips
    • INTRODUCTION TO SUBSTATION EARTHING
    • Maintenance of GIS (Gas-Insulated Switchgear)
    Electric Know How
    • Home
    • Generation
      • Hydropower Station
      • Thermal Power Station
      • DISTRIBUTED ENERGY SOURCES
      • Diesel Generator
      • Industrial Tools
      • DC System-Generating Stations
    • Transmission
      • High Voltage DC Transmission
      • High Voltage AC Transmission
        • Transmission line – An Overview
        • TRANSMISSION TOWER CONFIGURATION
        • Transmission Towers-Key Features
    • Distribution
      • ⚡ Understanding Electrical Distribution Systems: Basics to Architecture
      • ⚡ Top 5 Faults in Distribution Lines and How to Fix Them
      • 🛠️ Distribution Transformer Maintenance: Checklist and Tips
    • Protection
      • Power System Protection
        • Types of Fault in Power System
        • Relay Setting Calculation for Substation
        • Circuit Breaker
          • Nameplate details of SF6 Circuit Breaker
          • Major parameters of a circuit breaker
          • What is the use of an anti-pumping relay?
          • What is an IR Value Test in a Circuit Breaker? An overview
          • Testing of Circuit Breaker
        • Key Components of Control & Relay Panel
          • Relay Setting Calculation for Substation
          • Trip Circuit Supervision Relay
          • Three Phase Control Wiring
        • Switching Surges and Its Remedies
      • OVERVIEW OF TRANSFORMER PROTECTION
        • Differential Protection of Transformer
      • OVERVIEW OF GENERATOR PROTECTION
      • Distance Protection
      • Electrical Safety
    • Switchgear
      • Electrical Sub-Station
        • BATTERY SYSTEM IN GRID SUBSTATION
        • Operation of Float Cum Boost Charger
        • Protection Circuitry of Battery Charger
        • Power Transformer
          • INSULATION RESISTANCE OF TRANSFORMER
          • WTI AND OTI in Power Transformer
          • Transformer Oil Dielectric strength
          • On Load Tap Changing of Transformer
          • TRANSFORMER MAINTENANCE
        • Sub-Station Operation
        • Multiplying Factor for Energy Meter
      • Current Transformer
        • Nameplate Detail of Current Transformer – A Detail Guide
        • Current Transformer Knee Point Test – A Detailed Overview
        • What is a Current Transformer Polarity Test- Detailed Guide
        • Ratio test of Current Transformer
      • Potential Transformer
      • Isolator in Substation
        • Nameplate Detail of Isolators/Dis-connectors- A Detail Guide
      • Electrical Busbar
      • Insulators
      • Clamps and Connectors
      • Fire Fighting System
      • Lightening Arrester
        • LCM Test of a Lightning Arrestor – An Overview
      • Gas Insulated Substation
        • Local Control Cubicle
        • SF6 circuit breaker gas compartment
        • Maintenance of GIS (Gas-Insulated Switchgear)
    • Q&A
      • FAQS ON Current Transformer
      • POWER SYSTEM
      • FAQ ON BUSBAR
    Electric Know How
    Home»Switchgear»Isolator in Substation
    Switchgear

    Isolator in Substation

    madhusmitaBy madhusmita25 November 2022Updated:2 February 2024No Comments4 Mins Read
    Facebook Twitter Pinterest LinkedIn Tumblr Email
    Share
    Facebook Twitter LinkedIn Pinterest Email

    Definition

    •Isolator is a mechanical switch that isolates a part of the circuit from the system when required. Isolators are used to open a circuit under NO LOAD conditions.

    •Isolators are generally used on both ends of the breaker for safe repair or replacement of the circuit breaker. The construction and operating mechanism vary based on the voltage level at which isolating switch needs to be operated.

    There is a need for proper installation, alignment, and maintenance of disconnecting switches of ratings for smooth functioning.

    Table of Contents

    Toggle
    • Types of Isolator
    • Summary

    Types of Isolator

    According to system requirements:

    A. Horizontal Break

    a. Double Break Isolator

    b. Single Break Isolator (center break)

    B. Vertical Break

    C. Pantograph type Isolator.

    According to the layout:

    A. Single Isolator (SI)

    B. Double Isolator (DI)

    C. Beam-mounted

    D. Off Set (Tandem) Isolator

    E. Isolator with E/S, Double E/S, without E/S

    These are some of the common types of isolators used in substations. The selection of isolators depends on various factors, including voltage level, fault current interruption requirements, space limitations, and operational needs, among others. It’s important to consult with qualified engineers and follow relevant standards and regulations when designing, installing, and operating isolators in a substation.

    Parts of Isolator

    • Moving Contact
    • Moving Contact Arcing Horn
    • Copper Jaw
    • Lever Arm
    • Clamp
    • Male Contact
    • Jumper Pad
    • Insulator Stack
    • Elevator Plate
    • Base Channel
    1. Isolator Blades: The isolator blades are the main components of the isolator that open or close the electrical circuit. The isolator blades are mounted on a rotating shaft and can be operated manually or by a motor.
    2. Drive Mechanism: The drive mechanism is responsible for operating the isolator blades. It typically consists of a motor, gear system, and coupling arrangement. The motor provides the driving force, while the gear system converts the motor’s rotational motion to linear motion, which is used to open or close the isolator blades. The coupling arrangement connects the motor and gear system to the isolator blades and ensures proper synchronization of their movements.
    3. Control Panel: The control panel houses the electrical components and control devices that are used to operate the motorized isolator. It typically includes motor starters, control switches, protective relays, and other electrical components. The control panel is used to start, stop, and control the motor that operates the isolator blades, and it may also include monitoring and signaling devices to indicate the status of the isolator.
    4. Operating Mechanism: The operating mechanism is used to manually operate the motorized isolator in case of motor failure or emergency situations. It typically includes a manual crank or handle that can be used to manually rotate the isolator blades and open or close the circuit. The operating mechanism provides a backup method for operating the isolator when the motorized operation is not available.
    5. Mounting Structure: The mounting structure provides mechanical support and stability for the motorized isolator. It typically includes a sturdy framework, base plates, and other structural components that are designed to withstand the mechanical stresses and environmental conditions in a substation. The mounting structure is designed to ensure proper alignment and positioning of the isolator blades for reliable operation.
    6. Earth Switch: The earth switch is a part of the motorized isolator that is used for earthing or grounding of the electrical circuit. It typically consists of a separate blade or contact that is connected to the ground or earth. The earth switch can be operated manually or by motor, and it is used to provide a direct path for current to flow to the ground, ensuring that the electrical circuit is safely grounded during maintenance or repairs.
    7. Interlocking Devices: Interlocking devices are safety features that are designed to prevent unsafe operations or conditions. They are typically integrated into the motorized isolator to ensure proper sequencing of operations and prevent incorrect or unsafe operations. Interlocking devices may include mechanical, electrical, or electronic devices that prevent the motorized isolator from being operated in an unsafe or incorrect manner.

    Summary

    It’s important to note that the specific design and features of motorized isolators may vary depending on the manufacturer, model, and application requirements. It’s crucial to follow the manufacturer’s instructions, relevant standards, and regulations, and consult with qualified engineers during the design, installation, and operation of motorized isolators in a substation to ensure safe and reliable operation.

    Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
    Previous ArticleInsulators
    Next Article Lightening Arrester
    madhusmita
    • Website
    • Facebook
    • Instagram
    • LinkedIn

    Related Posts

    ⚡ Smart Grid in Distribution: Role, Challenges & Indian Scenario

    16 May 2025

    ⚡ Power Factor Correction in Distribution Systems

    16 May 2025

    ⚡ Voltage Drop in Distribution Lines: Causes, Calculation & Correction

    16 May 2025

    Comments are closed.

    Archives
    Categories
    • Distribution (15)
    • Generation (10)
    • Protection (24)
    • Q&A (7)
    • Switchgear (48)
      • Nameplate Details (2)
    • testing (11)
    • Transmission (20)
    Recent Posts
    • ⚡ Cable Types in Distribution: XLPE vs PILC vs Aerial Bundled Cables
    • ⚡ Smart Grid in Distribution: Role, Challenges & Indian Scenario
    • ⚡ Power Factor Correction in Distribution Systems
    • ⚡ Understanding Distribution Protection: Fuses, Relays & Reclosers
    • ⚡ Voltage Drop in Distribution Lines: Causes, Calculation & Correction
    Certification Course
    Electric Volt

    Quick Links

    • Home
    • About Us
    • Contact Us

    Post Categories

    • Generation
    • Transmission
    • Distribution
    • Protection
    • Switchgear
    • Q&A

    Vip Link

    • Privacy Policy
    • Disclaimer
    • Terms and Conditions

    Contact Us

    • ele.mamohanty@optcl.co.in
    Linkedin